Engineering reference · Scope boundary
Scope & limitations.
A clear boundary is part of a reliable engineering tool. This page describes what the current application models, what it does not model, and when a different engineering package is more appropriate.
Current capabilities
What the current application supports.
Structured PFD/BFD drafting
Place supported equipment and unit-operation nodes, connect ports with streams, label the model, and arrange the flowsheet on a drawing canvas.
Orthogonal stream routing
Routes use horizontal and vertical segments with visibility-graph obstacle avoidance, designated corridors for backward/recycle flows and trunk convergence at shared destination ports.
Steady-state component balance
The current solver operates on a molar basis. Stream component flow rates are expressed in kmol/h for the registered components.
Recycle convergence
Supported recycle networks can be iterated using direct, damped or Wegstein methods. Tear streams and convergence diagnostics can be inspected.
JSON-based project persistence
.pfdoc documents store the flowsheet in a readable JSON-based format, including model data and routed geometry.
Diagram and engineering outputs
The Free tier includes watermarked diagram SVG export. Full A3 engineering-sheet export and CSV stream-table export are planned Pro capabilities, not currently available Pro services.
Technical scope
Technical boundary by domain.
The current model focuses on connected component-flow calculations and drawing. It does not attempt to replace domain-specific simulation or design packages.
| Domain | Current support | Not supported |
|---|---|---|
| Material balance | Steady-state component molar-flow calculations across supported feeds, mixers, splitters, separators, reactors, blocks and product sinks. | Transient accumulation, dynamic operation, or a general-purpose mass-basis mineral-processing solver. |
| Thermodynamics | Component-flow bookkeeping and configured unit-operation specifications. | VLE, flash calculations, phase equilibrium, activity-coefficient models, equations of state, enthalpy and rigorous physical-property calculations. |
| Energy | No energy-balance solver in the current scope. | Heat duties, energy balances, heat integration and thermal design. |
| Equipment design | Flowsheet-level representation of supported equipment and unit operations. | Mechanical design, vessel sizing, pump selection, exchanger sizing, column design, hydraulics and pressure-drop calculations. |
| P&ID and controls | PFD/BFD-oriented process representation. | Instrument indexes, control loops, piping classes, line lists, valve specifications and P&ID lifecycle workflows. |
| Process safety | No process-safety analysis capability is claimed. | HAZOP, LOPA, consequence modelling, relief-system design, SIL verification or operating-procedure approval. |
| Mineral processing | Molar-basis component flow modelling only, subject to the available unit models. | Mass-basis solids accounting, mineral liberation, size-by-size balances, grade/recovery modelling and mineral-specific separation models. |
Mineral-processing mass-basis workflows are not part of the current solver. Any future addition should be treated as a separately specified capability, not assumed to be available from the molar-basis model.
Model conventions
Model and calculation conventions.
- Steady state
The solver calculates a steady-state solution. It does not track inventory accumulation or time-dependent behaviour.
- Molar basis
Stream component flow rates use
kmol/h. Do not enter mass rates as though they were molar rates. - Component registry
Stream and reaction specifications refer to registered component identities. Molecular-weight data must be entered consistently with the application’s component-registry convention.
- Reaction specification
Key-component conversion and stoichiometric coefficients describe the configured reaction model. The user remains responsible for supplying chemically valid, balanced stoichiometry and appropriate component data.
- Split and recovery units
Separator-style unit operations represent configured component splits/recoveries. They do not calculate phase equilibrium or separation performance from thermodynamics.
- Recycle solution
Iterative convergence is numerical, not proof that the process model or specifications are physically valid. Review convergence status, tear streams and the resulting component flows.
Diagram quality
Routing behaviour and drawing review.
- Orthogonal geometry
Stream paths are composed of horizontal and vertical segments. The router aims to avoid equipment, labels and stream-number diamonds.
- Backward and recycle streams
Routes can use designated corridors to reduce crossings through forward-flow equipment rows.
- Stream-number placement
Stream diamonds are positioned on eligible straight horizontal sections to preserve legibility.
- Shared destination ports
Multiple incoming streams can converge through a common trunk before reaching the destination port.
- Sheet boundaries
Nodes or targets positioned outside the configured sheet boundary may use fallback routing. Keep equipment inside the drawing area and inspect the final geometry.
Automatic routing is a drafting aid, not an engineering approval step. Review crossings, labels, arrow directions, stream tags and the final printed sheet at the intended output size.
Current known issues
Known limitations to check.
Generic unit glyphs
Some distillation and flotation units may currently render with generic block geometry even when their balance behaviour uses a configured split/recovery model. Confirm that the symbol communicates the intended unit operation before issuing a drawing.
Dense corridor spacing
In some dense multi-stream layouts, corridor-routed edges may be closer together than desirable. Inspect parallel runs and labels at normal and print scale.
Out-of-sheet routing
Targets outside the active sheet boundary may fall back to direct or fallback routing. Keep nodes within the drawing area and review any route that approaches the sheet edge.
Tool selection
When another tool is the right choice.
Use software that matches the calculation, design and governance requirements of the task. The examples below are indicative tool categories, not endorsements or a substitute for checking suitability.
| If the work requires… | Consider… |
|---|---|
| VLE, flash, thermodynamic properties or rigorous process simulation | Aspen Plus, DWSIM, ChemCAD or PRO/II. |
| Heat-exchanger thermal rating or detailed thermal design | HTRI, vendor design software or a validated thermal-design method. |
| Mechanical and hydraulic equipment design | Applicable design codes, specialist engineering software, vendor calculations and project standards. |
| Dynamic simulation and control-system studies | Aspen Dynamics, DWSIM dynamics or a validated dynamic-process modelling platform. |
| P&ID, piping specifications and instrument lifecycle | AutoCAD Plant 3D, AVEVA, COMOS or the organisation’s controlled P&ID toolchain. |
| HAZOP, consequence modelling or process-safety studies | Facilitated process-safety methods and dedicated specialist tools, supported by competent practitioners. |
| Mass-basis mineral-processing balances | Validated spreadsheet workflows or mineral-processing packages until a dedicated mass-basis capability is released. |
Product availability
Free vs. planned Pro.
Free access is permanent. Pro is a planned offering at a target price of $49/month. The Pro features below are not available for purchase yet; release timing and final terms will be confirmed before launch.
| Capability | Free | Pro |
|---|---|---|
| Draw, connect and solve supported balances | Available | Included |
| Local browser save | Available | Included |
.pfdoc import and export | Available | Included |
| Diagram SVG export | Watermarked | Clean export planned |
| A3 engineering-sheet export | Not included | Planned |
| CSV stream-table export | Not included | Planned |
| Cloud save and cross-device sync | Not available | Planned |
Do not rely on cloud persistence until it is explicitly released. Keep local .pfdoc backups of important work.
Engineering responsibility
Verification remains part of the workflow.
Software output is only as reliable as the model, inputs, assumptions and verification applied to it. Before relying on a result:
- Confirm the component list, units, molecular weights, feed specifications and reaction stoichiometry.
- Check each unit’s specification and review solver diagnostics and recycle convergence status.
- Independently verify component balances and the overall process boundary, including purge and recycle definitions.
- Review the diagram, stream labels, routing and exported sheet at issue scale.
- Have the responsible engineer approve calculations and drawings under the applicable project procedures.
GCE-Flowsheet is a productivity aid. It does not replace engineering judgement, independent checking, applicable codes and standards, formal design reviews or professional sign-off.